Stormwater Drainage Wells
On this page:
What is a stormwater drainage well?
What is not a stormwater drainage well?
Why does EPA regulate stormwater drainage wells?
What are the minimum federal requirements for stormwater drainage wells?
What are stormwater drainage well best management practices?
This page will help owners and operators:
- Determine whether you have a stormwater drainage well
- Learn how to comply with regulations for stormwater drainage wells
- Find out how to reduce the threat to ground water from your injection well.
The general information may also be useful to state, tribal, and local regulators.
In general, owners and operators of stormwater drainage wells include:
- State, tribes, and local governments
- Public and private institutions
- Commercial and industrial facilities
- Community associations
- Private citizens
What is a stormwater drainage well?
Class V stormwater drainage wells are used for subsurface infiltration to manage surface water runoff (rainwater or snow melt). Stormwater drainage wells may have a variety of designs and are often referred to by names that include:
- Dry wells
- Bored wells
- Infiltration galleries
The names can be misleading so it is important to note that storm water drainage wells like any well is defined in the UIC regulations (40 CFR144.3) as:
A bored, drilled, or driven shaft whose depth is greater than the largest surface dimension; or, dug hole whose depth is greater than the largest surface dimension; or, an improved sinkhole; or, a subsurface fluid distribution system.
Stormwater infiltration systems with piping to enhance infiltration capabilities meet the UIC definition of a Class V well.
In 1999, EPA completed a study of Class V wells to develop background information for use by the Agency to evaluate the risks to underground sources of drinking water (USDWs) posed by Class V wells. The study describes 23 categories of Class V wells, including stormwater drainage wells, and characterizes their:
- Use
- Location
- Number
- Potential impacts to USDWs
- Regulatory requirements
What is not a stormwater drainage well?
Some types of infiltration systems do not meet the definition of Class V stormwater drainage wells. These generally:
- Are larger at their widest surface point than they are deep, or
- do not contain any perforated pipes or drain tiles to distribute and/or facilitate subsurface fluid infiltration, or
- do not include underground components that discharge fluids to the subsurface.
Stormwater surface impoundments are generally not considered Class V wells if they do not include dug, drilled, or driven shafts, or include a subsurface fluid distribution system.
Questions: | If Your Answer Is Yes... | If Your Answer Is No... |
---|---|---|
1. Do you operate a stormwater collection system that relies on infiltration to collect and dispose of storm water runoff? | Go to question 2. | You do not have a Class V stormwater drainage well. |
2. Does your infiltration system discharge to the subsurface? | Go to questions 3 through 6. | You do not have a Class V stormwater drainage well. |
3. Does your stormwater infiltration system consist of a drilled or driven shaft, or dug hole, or trench that is deeper than it is wide? 4. Does it rely on a naturally occurring sinkhole, a drywell, or a seepage pit for infiltration? 5.Does it include any subsurface piping, perforated piping, drain tiles, or any other underground components that discharge fluids to the subsurface? 6. Does it include any commercially manufactured stormwater infiltration devices, such as a detention vault, chamber, or other device designed to capture and infiltrate stormwater runoff below the surface of the ground? |
If the answer to any of these questions is yes, you have a Class V stormwater drainage well and are subject to Class V requirements. Review the following section on stormwater drainage wells and green infrastructure to learn more about stormwater management practices that are considered green infrastructure, and stormwater management practices that are considered Class V wells. | You probably do not have a Class V stormwater drainage well. |
Stormwater drainage wells and green infrastructure
Surface and ground water protection requires effective integration between the Clean Water Act and the SDWA. Recognizing that some stormwater infiltration practices are regulated as Class V wells under the UIC program, EPA issued a memorandum to provide clarification on which stormwater infiltration techniques meet EPA's Class V well definition. The June 2008 memorandum includes a Class V Well identification Guide intended to assist stormwater managers in determining which stormwater infiltration practices/technologies have the potential to be regulated as UIC Class V wells.
Why does EPA regulate stormwater drainage wells?
The Safe Drinking Water Act (SDWA) requires that EPA protect USDWs from injection activities. EPA has set minimum standards to address the threats posed by all injection wells, including stormwater drainage wells.
Stormwater injection is a concern because storm water may contain petroleum or other organic compounds that could harm USDWs. Other potential harmful contaminants include:
- Sediment
- Nutrients
- Metals
- Salts
- Microorganisms
- Fertilizers
- Pesticides
What are the minimum federal requirements for stormwater drainage wells?
This section outlines the minimum federal requirements for stormwater drainage wells. Some states have applied for and been granted authority to implement the Class V UIC Program in their state, including oversight of stormwater drainage wells, and may have more stringent requirements.
Visit the permitting authority page to find out what agency oversees Class V wells in your state. It is your responsibility to find out what the specific requirements are in your state.
Class V stormwater drainage wells are “authorized by rule,” which means they may be operated without an individual permit so long as:
- The injection does not endanger a USDW
- The owner or operator of the well submits basic inventory information about the well to their permitting authority
Inventory submission requirements vary by state. The required inventory information typically includes:
- Facility name and location
- Name and address of a legal contact
- Ownership of property
- Nature and type of injection well(s)
- Operating status of the well(s)
For more information, visit the page on minimum requirements, or contact your permitting authority.
If you have a new stormwater drainage well, you must contact your permitting authority before you begin construction.
For existing stormwater drainage wells, you must stop using the well immediately and contact your permitting authority to find out what you must do. In most cases, you will need to:
- Submit an inventory form
- Wait up to 90 days to allow the UIC program to authorize your well, after which you may continue using it (unless you are told otherwise)
Authorization to use the well expires once you have properly closed the well. Proper well closure, also referred to as well abandonment, is a procedure to ensure that the well will not endanger USDWs in the future. Depending on the well’s design, proper well closure could include:
- Backfilling with clean fill material
- Soil excavation
- Casing removal
- Grouting
Contact your permitting authority for specific instructions on properly closing the well.
What are stormwater drainage well best management practices?
Best management practices (BMPs) are physical, structural, and managerial practices that prevent or reduce the contamination of USDWs. The proper design and siting of a stormwater drainage well minimizes the likelihood of accidental or routine contamination resulting from either poor operational practices or misuse.
There are five general categories of BMPs for stormwater drainage well BMPs that can be implemented alone or in combination. The five general categories relate to:
- Siting
- Design
- Operation and maintenance
- Education and outreach
- Proper closure (plugging and abandonment)
The appropriateness and effectiveness of BMPs vary according to the type, design, setting, and operation of the well. Consult your permitting authority for additional information and to learn about location-specific BMPs.